Bearing replacement of the DC unit part of the Shimano 06 Antares DC / DC7 · 07 Antares DC7-LV
There is a silver cap on the part of the arrow of open and DC unit the side cover plate.
This is removed in such a flat-blade screwdriver.
Then you will see in the bearings.
You can easily remove it a little shake and bearings while tilting the reel in this state.
If if can not be extracted in this way you will need to remove the DC unit.
First, remove the three screws that secure the reel body and the DC unit.
When removing the DC unit from the reel body, please go to carefully remove it without unreasonable because there is a case where a little difficult to remove.
Then remove the silver cap on the DC unit central portion described above.
Then bearing is so fetch visible, replace the bearing for the exchange.
If the bearing is difficult to take out the handle knob cap remover you can easily exchange work be taken out as hooking using.
After bearing exchange, and fixed with screws the DC unit again, it is the last work completed if there is no problem to check the rotation of the spool.